For oil vapor removal; meets ISO 8573-1:2010 Class 1.
Overview
Features
- 100 to 1,000 SCFM
- Connection:
- 1 to 2" NPT
- 3" ANSI Flanged
- 232 PSIG pressure rating
- 122°F maximum air inlet temperature
- 35 to 122°F ambient temperature range
- Compressed air and gaseous nitrogen medium
- Materials of constructions:
- Pressure vessels: carbon steel, welded, ASME
- Seals: nitrile
- Adsorbing material: 100% activated carbon
- Recommended filtration requirements:
- Pre-filter: ISO 8573-1: 2010 Class 1, 0.01 micron, 0.01 mg/m3 carryover
- After filter: Solid particulates 1.0 micron
- 31 to 310lbs activated carbon
Description
The Parker CAT Activated Carbon Tower performs at an outlet oil level of .003ppm (.003mg/m3) with .01mg/m3 inlet concentration, for a 3.33:1 reduction. The unit is designed for a frost-free indoor installation in a non-hazardous environment. Separate fill and drain ports allow for quicker carbon replacement. The unit is standalone, and includes a pressure gauge, oil indicator, and ASME coded vessels.
Applications
- Food and beverage
- Pharmaceutical manufacturing and processing
- N2 membrane protection
- Air purity-critical environments
Documents